Access Control
IDE-DC300
Four-door access controller — Ethernet
The IDE-DC300 manages four doors and four readers from a single Ethernet-connected controller. Its field wiring uses pluggable screw terminals. For installations with doors cabled to a common point, it is available either as an enclosed controller or in a sheet-metal cabinet with an integrated power supply.
- Doors
- 4 doors
- 4 × Form C relay, 30 V DC / 5 A
- Readers
- 4 × Wiegand
- Independent channels
- Inputs / outputs
- 6 · 8
- LED and buzzer drivers
- Network
- Ethernet
- 10/100, RJ45

IDE-DC300-SMetal cabinet, integrated 12 V / 5 A supply
- 3.5 mm pluggable screw terminals
- Metal cabinet option: IDE-DC300-S
Enclosure options
Two enclosures, one controller
Both variants contain the same controller electronics and report the same device type to the management software. The suffix identifies the cabinet and power supply.
150 × 130 × 27 mmIDE-DC300
Four-door access controller, plastic enclosure; power supply not included
- Enclosure
- ABS, UL94-HB
- Dimensions
- 150 × 130 × 27 mm
- Power supply
- Not included
- Mains input
- —
- Mounting
- Surface-mounted, indoors
- Operating temperature
- 0 to +50 °C
- Humidity
- 10–90% RH, non-condensing
300 × 320 × 75 mmIDE-DC300-S
Four-door access controller, metal cabinet; integrated 60 W power supply
- Enclosure
- Sheet metal cabinet
- Dimensions
- 300 × 320 × 75 mm
- Power supply
- Included, 12 V / 5 A / 60 W
- Mains input
- 100–260 VAC, 50/60 Hz
- Mounting
- Wall-mounted, indoors
- Operating temperature
- 0 to +40 °C
- Humidity
- 20–90% RH, non-condensing
Photos are shown at approximately the same scale.
In the field and in operation
Key features
The controller makes the decision, so a network or server outage never stops the door.
Four doors on one controller
Four Form C relays, four independent Wiegand reader channels and six isolated inputs serve four doors. Each door has a reader LED and buzzer output. A single controller reduces the number of network connections and devices to configure and maintain.
4 relays · 4 readers · 6 inputs
Interlock decisions made locally
Door interlock is evaluated on the controller as part of the access decision. A door can be denied while another door in its interlock group is open or being granted access, without relying on a server round trip.
Applied in both directions
Access control continues during network outages
Credentials, permissions and schedules are stored on the controller. All four doors continue to make local access decisions while offline. The controller buffers up to 200,000 access events and sends them when connectivity returns.
200,000 offline records
Controller-wide emergency release
A configured input can hold all four doors in the released state for egress until the input condition clears.
All four doors at once
Automatic card-format recognition
The controller recognises supported 26-, 34-, 35- and 37-bit formats, including HID H10306, H10304, Corp 1000, Honeywell/Northern and iCLASS. Raw-value fallbacks are available for HID Prox, Mifare CSN and iCLASS UID. Each reader can use a different supported card format.
A card format per reader
Direct system integration
The controller provides both an HTTP server and an HTTP client. It can post live access events and buffered events to an external system, or an external server can retrieve them using a fetch-and-acknowledge exchange. The published protocol includes exact sample messages and a runnable reference receiver.
HTTP push and pull
Remote firmware updates with automatic recovery
The management software can deploy firmware across a fleet. Updates can be applied automatically, with a configurable check interval and time of day, so that they are installed outside working hours. If the updated firmware fails to start, the controller automatically reverts to the previous working version.
Scheduled update window
Alarm functions are built into the controller
A motion sensor connects to a controller input and a siren is driven from a controller output. Alarm partitions are armed and disarmed by presenting a card at the door reader. There is no separate alarm panel to buy and no integration between two systems to build.
Armed and disarmed by card
“Why did the door not open?” is answered in the log
When a request is refused, the reason is recorded with it: was the card unrecognised, does the user lack permission, was the attempt outside the permitted hours? Complaints and incidents are investigated directly from these records.
11 distinct refusal reasons
Every site is managed from one place
The controller opens the secure connection to the management server itself. No fixed public IP, port forwarding or VPN setup is required; controllers in different buildings and cities are managed from the same screen.
No open ports or VPN
Pluggable field terminals
Field connections use 3.5 mm pluggable screw terminals. Each relay has NC, COM and NO connections, and each reader has a dedicated six-position terminal block. A terminal block can be unplugged when replacing the controller, without disconnecting its individual wires.
3.5 mm pluggable terminals
Technical detail
Specifications
- 40,000
- Credentials (cards, PINs and mobile)
- 5,000
- Permission rules
- 5,000
- Schedules
- 60,000
- Usage-limited credentials
- 200,000
- Offline access-event capacity
A card, PIN and mobile credential registered to one person count as three credentials. They share one identity, permission set and anti-passback position.
The controller's behaviour when the log is full can be selected. Preserving the existing records means the oldest entries are never overwritten and new requests are refused; keeping access available means new events overwrite the oldest records. The first option gives priority to the existing audit history, the second to entries continuing and current events being recorded.
The maximum number of permissions per person is configurable. Higher limits reduce credential capacity as shown below:
- Permissions per person
- Credentials
- 16
- 40,000
- 32
- 40,000
- 48
- 29,000
- 64
- 23,000
- 128
- 12,500
- 255
- 6,500
Access decisions are made on the controller without a server round trip.
Access control functions
Door interlock (mantrap)
Any subset of the four doors can form an interlock group. Access at one door is denied while another group member is open or in an active grant cycle. The rule applies in both directions.
Multi-credential authorisation
Credentials from 2–8 different authorised people are required within a configurable 1-second to 1-hour window. Reader groups can be configured so entry uses two readers while exit uses one. Re-presenting the same credential does not count.
Anti-passback
Zone status is replicated directly between controllers without a server connection, allowing site-wide global anti-passback. Configurable per door. Hard and soft anti-passback are both supported.
Fire and emergency release
A configured input holds all four doors released for egress until the condition clears.
Alarm partitions
Scenarios are grouped into partitions. A partition is armed or disarmed with an authorised credential; motion in a disarmed partition produces no action.
Exit button
Any input can be configured as a direct exit-button input.
Door contact
Accepts a turnstile-rotation signal, and detects forced opening and doors held open, with a configurable timeout. If no door contact is fitted, its input remains available for another function.
Time schedules
Schedules, holidays and date ranges are evaluated on the controller.
Usage-limited credentials
A credential is valid for a fixed number of entries, counted per door.
Scenario engine
Rules stored on the controller, triggered at set times or by input state, door events and access events. A triggered scenario can run a relay for a set period, sound the buzzer, drive a relay on another controller, or arm and disarm another scenario.
Detailed access records
When access is refused the reason is recorded: unrecognised card, missing permission, use outside the schedule, exhausted usage allowance, anti-passback rule, inactive or expired record, facility-code mismatch, offline state, door interlock and authentication failure. Forced opening, doors held open and the return to normal are also recorded.
Facility-code check
An accepted facility code can be set per reader. A card whose code does not match is refused, and the reason is recorded as a facility-code mismatch.
Reader feedback
Separate LED and buzzer patterns can be defined per reader for accepted and refused attempts.
Card number format
The facility code and card number can be read as separate fields, or as the long number printed on the card.
Before clock synchronisation
Configurable behaviour before the clock is synchronised.
Offline behaviour
Configurable behaviour when the server is unreachable.
Per-door settings
Each door can be configured independently for unlock pulse duration; relay mode (pulse, toggle or latch); default and power-restore states; early relock on door opening; an option to count access only when the door opens; door-open timeout; anti-passback mode and zone; interlock group; and usage counting.
Doors, readers and I/O
- Doors
- 4
- Card readers
- 4 × Wiegand, independent channels
- Relay outputs
- 4 × Form C (NC / COM / NO), dry (voltage-free) contacts
- Max. switching voltage
- 30 V DC
- Max. switching current
- 5 A
- Inputs
- 6 × optically isolated, for dry contacts; configurable debounce
- Reader outputs
- 8 outputs: 4 LED and 4 buzzer controls
- On-board buzzer
- Yes
- Status indication
- 2 × addressable RGB LEDs
- RTC
- Battery-backed during power loss; synchronised by NTP
The relay contacts include transient suppression and are intended for low-voltage lock loads. Mains switching is not supported.
Connection interfaces — 3.5 mm pluggable screw terminals
| Terminal | Ways | Signals |
|---|---|---|
| Power input | 2 | IN+, IN− |
| Relay 1–4 | 3 each | NC, COM, NO |
| Reader 1–4 | 6 each | D0, D1, LED, buzzer, IN+, IN− |
| Inputs | 2 each | IN1–IN2, IN3–IN4, IN5–IN6 |
| RS-485 | 2 | A, B |
| Ethernet | RJ45 | 10/100, shielded |
Cable and distance
| Connection | Cable | Maximum run |
|---|---|---|
| Wiegand data | Shielded AWG22 twisted pair | 150 m |
| RS-485 | Shielded AWG24 or heavier twisted pair; 120 Ω termination at both ends | 1,200 m at the default 9,600 baud; approximately 200 m at 500 kbps |
| Ethernet | Cat-5e | 100 m |
| Reader power | Distance depends on supply voltage drop; see below | — |
Reader power. The reader draws from the controller supply. The maximum cable length is limited by conductor resistance. For a 12 V supply and a maximum 2 V voltage drop:
| Reader current | AWG22 | AWG20 | AWG18 |
|---|---|---|---|
| 100 mA | 190 m | 300 m | 475 m |
| 150 mA | 125 m | 200 m | 315 m |
| 250 mA | 75 m | 120 m | 190 m |
For long cable runs, check both the data limit and the reader power limit. Use the shorter distance. The terminals accept conductors up to AWG16, so a suitable cable can run directly to the controller.
Communications
- Ethernet
- 10/100, RJ45 with integrated magnetics, shielded
- Wi-Fi / Bluetooth
- Not fitted — wired installation
- Data at rest
- Encrypted on the controller
Power
- Input
- 12–24 V DC
- Protection
- Reverse-polarity, overvoltage and surge protection
- Controller consumption
- 1.0 W typical, 3.1 W maximum — approximately 80 mA and 260 mA at 12 V
- Reader supply
- Same voltage as the controller input (12–24 V); 250 mA maximum per reader
- Recommended supply
- 12 V / 2 A or 24 V / 2 A minimum
- Backup battery
- CR1220 coin cell; backs up the real-time clock (RTC) only; does not power the controller.
With four readers at 250 mA the controller draws about 1.26 A at 12 V, which is why 2 A is the recommended minimum.
The relay contacts are volt-free. The lock is powered from its own supply and the contact only switches it, so lock current is not part of these figures and must be provided separately.
The IDE-DC300-S variant includes a sheet-metal cabinet and an integrated 12 V / 5 A / 60 W supply (100–260 V AC, 50/60 Hz, 85% efficiency, EN 62368-1).
Integration and interfaces
On-board HTTP server
Accepts direct HTTP commands to release a door, read status, and read or change settings.
HTTP client — push
Posts live and buffered access events to an external server, along with heartbeats and input telemetry.
HTTP server — pull
Allows an external server to retrieve and acknowledge events in separate steps.
Management protocol
MQTT over TLS. The controller opens the connection; no open port, port forwarding or VPN is required.
Serial bus
RS-485, half-duplex; up to 500 kbps and 256 nodes; ±18 kV IEC ESD.
Also available
TCP and UDP
Discovery
mDNS / DNS-SD
Device health
Uptime, restart reason, processor temperature and memory status are reported.
Network rollback
If an incorrect static IP is applied the controller does not become unreachable; it reverts to DHCP.
Documentation
Published protocol specification, exact message samples and a runnable reference receiver.
Mechanical and environmental specifications
| Feature | IDE-DC300 | IDE-DC300-S |
|---|---|---|
| Enclosure | ABS, UL94-HB | Sheet metal cabinet |
| Dimensions | 150 × 130 × 27 mm | 300 × 320 × 75 mm |
| Power supply | Not included | Included, 12 V / 5 A / 60 W |
| Mains input | — | 100–260 VAC, 50/60 Hz |
| Mounting | Surface-mounted, indoors | Wall-mounted, indoors |
| Operating temperature | 0 to +50 °C | 0 to +40 °C |
| Humidity | 10–90% RH, non-condensing | 20–90% RH, non-condensing |
| Ingress protection | Indoor use | Indoor use |
The integrated power supply determines the narrower environmental range of the IDE-DC300-S variant.
Ordering
- IDE-DC300
- Four-door access controller, plastic enclosure; power supply not included
- IDE-DC300-S
- Four-door access controller, metal cabinet; integrated 60 W power supply
Both variants contain the same controller electronics and report the same device type to the management software. The suffix identifies the cabinet and power supply.
Warranty
The product is warranted against defects in materials and workmanship for two years from the date of delivery.
The following are excluded from this warranty:
- The RTC backup battery
- Damage caused by surges, lightning, overvoltage or a supply outside the specified input range
- For IDE-DC300-S, the integrated power supply, which has a separate manufacturer's warranty
How it connects
Decided at the door, recorded centrally
The controller opens the secure connection to the management server itself. No open port, port forwarding or VPN is required.
Reader and door
A card or PIN is read at the door's Wiegand reader.
The controller decides
Permissions, schedules and anti-passback are evaluated on the controller, and the lock relay is driven.
Ethernet
Events travel to the management server as MQTT over TLS, and wait on the controller while the link is down.
Management server
Records are collected centrally and can be passed to other systems over MQTT/HTTP.
Not sure which controller fits?
Tell us the door count, the reader type and the network you have, and we will size it with you.